A static grounding control system designed for tankers or drums, ensuring safety during hazardous material loading and unloading.
In hazardous area loading operations, a visible metal-to-metal connection does not necessarily mean a true earth is present.
Paint coatings, corrosion, grease, insulated components or vehicle construction can create a false grounding path. In such cases, static charge may remain undetected, significantly increasing the risk of ignition.
True earth verification is therefore essential for safe tanker loading operations.
Earthing Pro GE utilizes a triple-verification detection principle to ensure a true connection to the earth, effectively dissipating static electricity and preventing ignition risks. Its operating principle includes the following three verifications:
Ensures that the device is properly grounded to the earth, preventing false grounding due to coatings, corrosion, or other factors.
Verifies that the static grounding clamp is securely connected to the tanker, container, or other grounded structures to ensure effective static discharge.
Confirms that the grounding loop resistance is less than 10Ω, ensuring the grounding system has a low-impedance characteristic for safe and rapid static discharge to earth.
With these three verifications, Earthing Pro GE provides comprehensive grounding verification and interlock control, offering robust static protection for loading, unloading, and filling operations worldwide.
Continuous grounding monitoring
Visual and audible grounding status indication
Integrated self-diagnostic system
Designed for hazardous area applications
|
Ground Resistance Threshold |
≤ 10 Ω (typical) |
|
Certification |
II2(1)G Ex db ia [ia Ga] IIC T6 Gb II2(1)D Ex ia tb [ia Ga] IIIC T80℃ Db |
|
Outputs |
On-off signal,10A 250VAC/5A 30VDC |
|
Supply Voltage |
24V~60V or 85V~250V |
|
Operating Temperature |
-20 °C to +60 °C |
Tanker Loading/Unloading, Drum Container Hazardous Material Handling, Storage, and Filling
Our equipment is designed for the safe handling and storage of hazardous materials, suitable for various liquid and gas product loading and unloading operations. The areas of application include:
Tanker Loading/Unloading: Ensures effective static discharge during tanker operations, preventing fire or explosion risks due to static electricity.
Drum Container Hazardous Material Handling: Provides static grounding and overfill protection for hazardous chemicals in drum containers, ensuring safety during loading and unloading.
Storage and Filling Operations: Ensures safe transfer of liquids or gases in various storage and filling environments, preventing static accumulation and improving operational safety.
Our products provide comprehensive static protection globally, ensuring compliance with international safety standards.
Yes.Standars such as ATEX,IECEx,NFPA and API requie effective static discharge during hazardous operations involving flammable materials.
Uncotrolled static discharge may cause sparks,vapor ignition,equipment damge,and serious safety incidents.
Key factors include hazardous area classification,application type,required certifications,and system integration requirements.
We are manufacturer with our own production and engineering team,proving direct factory support to global customers.